100E   The hardware lock has been disconnected, removed,

100E    faulty or cannot be detected.

100S    1. If hardware lock has been removed or loosened,

100S    please attach the hardware lock to the computer's

100S    parallel port connector.

100S    2. Install the hardware lock driver from the CD-Rom,

100S    if you have not done so.

100S    3. Should the hardware lock be damaged, please report

100S    to your dealer.

 

101E    Authorization File is incompatible or corrupted.

101S    1. Please copy the original Authorization File from

101S    the Install CD-Rom/Disk to the main directory where

101S    the program is installed.

101S    2. If the Authorization File is incompatible, please

101S    contact your dealer.

 

103E   -

103E   Cannot support unlimited ('M') part qty.

103S   Change the unlimited part qty to be limited.

 

104E   -

104E   Cannot support coiled stocks.

104S   Change the coiled stock to be normal regular stock.

 

105E   -

105E   Cannot support unlimited ('M') part qty for tasks

105E   with multiple distinct parts.

105S   Change the unlimited part qty to be limited.

 

106E    -

106E   Cannot support coiled stocks for tasks

106E   with multiple distinct parts.

106S   Change the coiled stock to be normal regular stock.

 

107E   Number of distinct stock sizes cannot be <=0.

107S   Specify a num (>=1).

 

108E   Number of distinct parts is greater than the actual

108E   number of parts in the task file.

108E   Add more parts in task file.

 

109E   Number of distinct parts cannot be <=0.

109S   Specify a num (>=1).

 

110E

110E   Invalid number of parameters.

110E

110E   Format : program_name task_name

110E

110E   Example : NESTPRO task1

 

112E    For "UpdateNest", the part output format should be

112E    set to "DWG".

112S    Run "SYSDATA" to re-set the "File Format" to "DWG".

 

114E   Coiled stock and unlimited ('M') part qty

114E   is not supported.

114S   1. Either change the stock definition.

114S   2. Or change part qty "M" to a fixed qty.

 

115E    Assembly/Cluster needs more qty for the following part -

115S   Please re-define the part qty.

 

130E    No .DXF files found in directory -

130D   The AutoNEST data files cannot be found in default

130D    directory. Check part directory in <SYSDATA>.

 

131E    No .VEC files found in directory -

131D   The AutoNEST data files cannot be found in default

131D    directory. Check part directory in <SYSDATA>.

 

133E    No .SYM files found in directory -

133D    The AutoNEST data files cannot be found in default

133D    directory. Check task directory in <SYSDATA>.

 

134E    No .DWG files found in directory -

134D   The AutoNEST data files cannot be found in default

134D    directory. Check part directory in <SYSDATA>.

134D    Only applicable for AutoCAD.

 

136E    No .STK files found in directory -

136D   The AutoNEST data files cannot be found in default

136D    directory. Check part directory in <SYSDATA>

 

140E   Can't open file for read -

140D   The error will happen when AutoNEST cannot open

140D    the data file for read.

140D    Eg, In <Nesting>, please make sure that the task file

140D    and the part files are in the specified default

140D    directories.

 

141E   Can't open AutoNEST file for read -

141D   The AutoNEST supporting files are missing or corrupted.

141S    Check the AutoNEST distribution diskettes, and re-load

141S    the necessary files onto the hard-disk.

 

142E   Can't open file for read -

142D    Need to create the above data file.

 

143E    Authorization file not found.

143S   Please consult your dealer.

 

144E    All concurrent user licenses are currently being used.

144S   Please wait a while until one of the licenses has

144S    been released.

144S   You can also contact your dealer to increase the

144S    network concurrent user licenses.

 

145E   Your current license is not for this product.

145S   Please contact your dealer.

 

146E    Trial license has expired.

146S   Please contact your dealer.

 

147E    Authorization License Code not found.

147S    Submit the "Locking Code" and the

147S    "License Code Request Form" duly filled-in to your dealer.

 

148E   The system date has been tampered with.

148S   Please contact your dealer.

 

149E   Can't open file for read -

149D   The error will happen when AutoNEST cannot open

149D   The data file for read.

149S   1. The Task must be NESTED first before Auto-Bridge can be

149S   performed.

149S   2. Make sure that the Part & Task directories are correctly

149S   specified in the SYSDATA.

 

150E   Can't open file for write -

150D   The error will happen when AutoNEST cannot open

150D    the data file or supporting file for write.

150S    1. Run Out of File Handle, increase the "FILE" field in

150S    config.sys.

150S    Eg FILES=20

150S    2. Hard Disk Full.

 

151E   Can't open file for append

151D   The error will happen when AutoNEST cannot open

151D    the data file or supporting file for write.

151S    1. Run Out of File Handle, increase the "FILE" field in

151S    config.sys.

151S    Eg FILES=20

151S    2. Hard Disk Full.

 

153E    The AutoNEST file is corrupted -

153E    Check the AutoNEST distribution diskettes, and re-load

153E    the necessary files onto the hard-disk.

 

154E   The file is corrupted -

154S   Report to AutoNEST dealer

 

155E   The following part(s) cannot be found in the job file.

 

156E    No part found in the job file.

 

157E    No part selected.

 

158E    No stock selected.

 

159E    Cannot find job file, therefore ViewNEST terminates here.

 

160E    "Pre-defined" parts cannot be read.

160D   This is a trial version, only "pre-defined" parts

160D    in the default "...\parts" directory can be nested.

160S    Change the "Part/Ir-Stock Directory" to the

160S    installation default "...\parts" directory and try again.

 

201E    No suitable stock size at all

201D    During nesting if all the declared stock sizes are

201D    found to be too small to nest even one or a pair of the

201D    smallest part in the task, this message will be displayed.

201S   Either increase the stock sheet size or nest smaller parts.

 

202E    Number of distinct parts exceeds 1000.

202D    The number of distinct parts submitted in the task file

202D    has exceeded the limit of 1000.

 

203E    Number of distinct stocks exceeds 500.

203D    The number of distinct stocks submitted in the task file

203D    has exceeded the limit of 500.

 

204E    Part profile has more than 1500 vertices -

204D   The number of vertices in one of the profile of the part

204D    has exceeded the maximum number allowed : 1500.

 

205E   No nesting layout meets minimum utilization ratio requirement.

205D   All nesting layouts are abandoned.

205S   Either change stock size or set a lower minimum utilization ratio

 

206E    Ir-stock profile is out of processing limit.

206D   This may be due to too many vertices in the ir-stock

206D    profile or too many holes defined inside the ir-stock.

206S   Please simplify the ir-stock profile or try to reduce

206S    the no of holes inside the ir-stock.

 

300E    Incompatible AutoNEST version -

300D    Error happens when data file is from a different version

300D    of AutoNEST. For eg, the data file for AutoNEST V9

300D    will contain the following comment line :

300D    "# AutoNEST V9"

300D   The Release no is used to check the compatibility of

300D    different formats of data files between different releases.

300D    AutoNEST provides downward compatibility for all the

300D   data files.

300S   Please make sure all the files are not corrupted and

300S    the Release No is properly designated.

300S   If the file is corrupted, re-create the file.

 

305E    Profile(s) not closed or contains irregularities at the following location(s) :

305S   Either re-create the part/ir-stock or change the aperture

305S    value in ANEST.TOL.

 

306E    Profile(s) not closed or contains irregularities -

306S   Either re-create the part/ir-stock or change the aperture

306S    value in ANEST.TOL.

 

307E    Profile has lines that CROSSES over -

307D   The profile has some intersection lines.

307S   Either re-create the part or change the aperture value

307S    in ANEST.TOL.

 

308E    Profile has multiple SAME point -

308S   Either re-create the drawing or change the aperture value

308S    in ANEST.TOL.

 

312E    Profile is an ACAD Block - need to EXPLODE

312D    Only applicable for AutoCAD

312S    Re-create the drawing.

 

313E    Profile contains SPLINE segment -

313D    AutoNEST cannot accept profile with "SPLINE" segment

 

314E   Cannot convert DXF file -

314D    No profile can be detected on the LAYER or of the COLOR

314D    as specified in the SYSDATA "Input Part/Ir-Stock

314D    - Layer Setting".

 

315E    Part has TOO MANY EDGES -

315D   The constraints for vector compression is too tight.

315S    Change the constraints in ANEST.SYS.

315S    Either decrease minimum vector, increase total area, or

315S    increase relative global tolerance.

 

340E    Invalid file format for -

340S    Need to re-do

 

341E    Invalid file format for AutoNEST supporting file -

341S   Need to re-load from Diskette

 

345E   Cannot find "ANEST" layer in .DXF file -

345S   Need to save blocks in "ANEST" layer.

 

350E  Cannot find BLOCK in .DXF file -

350S   Need to re-create file

 

351E   Cannot find ENTITIES in .DXF file -

351S   Need to re-create file

 

352E   The .DXF file is above R12 version -

352D    Current software cannot support part/ir-stock

352D    DXF file above R12 version in Nest Manager environment.

352S    Save your part/ir-stock .DXF file as in R12 format.

 

400E   Not all parts are nested. It is due to either insufficient stock or

400E    no suitable stock size found.

400E    For more information, look at the summary.

 

401E    Pattern type of the following boundary data is wrong -

 

402E   Some parts are not nested as nested layout is below

402E   Utilization Factor.

402E   For more information, look at summary / schedule.

 

403E    Profile(s) not closed or contains irregularities at the following location(s) :

403D    This profile(s) will be ignored during nesting.

403D    Please check the profile(s) carefully, especially for

403D    outer-profile. Then save again to ensure correct nesting result.

 

404E    Current program can only support 0,90,180 degrees for stock

404E    grain direction. Other angles are ignored during nesting.

 

405E   The following changed or missing part(s) are recovered back:

405D   This is a trial version, only "pre-defined" parts can be nested.

405D   The "pre-defined" parts are not allowed to be modified.

 

406E   The following custom part(s) cannot be nested:

406D   This is a trial version, only "pre-defined" parts can be nested.

406S    Delete the custom part(s) from the Task and nest again.

 

500E    Not Enough Memory.

500D    Error due to insufficient memory to execute the AutoNEST program.

500S   Remove all unnecessary memory-resident programs.

500S    If in AutoCAD environment, check acad.pgp for memory reserve

500S    for all the programs. If possible, increase the memory reserve

500S    for the program. [For more information, please refer to AutoCAD

500S    Reference Manual, Appendix B]

 

600E    Pointer out of range

600D    Software bugs.

600S    Report to AutoNEST Dealer.

 

601E    Array Out Of Range

601D    Software bugs.

601S    Report to AutoNEST Dealer.

 

602E    Part expansion error -

602E    Expanded part contains invalid geometry

602D    The part after expansion to the specified cutting gap

602D    may contain invalid geometry or the number of vertices

602D    of the expanded part exceeds the limit : 350 vertices.

602S    Re-create the part by reducing the number of vertices.

602S   This may help to solve the problem. If not, Report it to

602S    AutoNEST Dealer.

 

652E   Nesting Error: -